REFERENCE

Microfluidics glossary

Short, plain-language definitions of the terms used in microfluidics product specifications, guides and papers. Each definition links to the source it was checked against.

A

Air–liquid interface (ALI) culture

A culture arrangement in which one side of a cell layer is exposed to air while the other side receives liquid medium, used to model barrier tissues such as the airway lining. Emulate lists air–liquid interface models among the uses of its stretchable Chip-S1.

Sources: Air-Liquid Interface Cultures to Model Drug Delivery through the Mucociliary Epithelial Barrier — Lee et al.; Advanced Drug Delivery Reviews (2023); Reconstituting Organ-Level Lung Functions on a Chip — Huh et al.; Science (2010); Emulate Chip-S1 Stretchable Chip — Emulate, Inc.

B

Biochip

A broad term for a miniaturised device, built with micro- or nanofabrication techniques, that is used to detect or analyse biological material such as cells, proteins or DNA. It covers biosensor chips, DNA and protein microarrays, and microfluidic lab-on-a-chip devices; this site currently focuses on research microfluidic chips.

Source: BioMEMS: state-of-the-art in detection, opportunities and prospects — Bashir R; Advanced Drug Delivery Reviews (2004)

C

Co-culture

Growing two or more cell types together so that they can interact. In two-channel organ chips, different cell types can sit on either side of a porous membrane.

Sources: Co-culture systems and technologies: taking synthetic biology to the next level — Goers et al.; Journal of the Royal Society Interface (2014); Chip-S1 Basic Research Kit Data Sheet (EN-020 Rev E) — Emulate, Inc.; Human cervix modeled in microfluidic organ chip fills key women's health gap — Wyss Institute for Biologically Inspired Engineering at Harvard University (31 May 2024)

Continuous and dispersed phases

In droplet microfluidics, the continuous phase is the liquid that surrounds and carries the droplets; the dispersed phase is the liquid broken up into droplets. The two liquids are immiscible.

Sources: Formation of dispersions using 'flow focusing' in microchannels — Anna et al.; Applied Physics Letters (2003); Machine learning enables design automation of microfluidic flow-focusing droplet generation — Lashkaripour et al.; Nature Communications (2021)

Cyclic olefin copolymer (COC) and cyclic olefin polymer (COP)

Optically clear thermoplastics used for moulded microfluidic chips. microfluidic ChipShop offers its herringbone mixer in Zeonor, a COP, or in polycarbonate.

Sources: Chips explained — microfluidic ChipShop GmbH; Microfluidic Chip Fabrication Services — microfluidic ChipShop GmbH; Herringbone mixer - Mixing and NP production - Fluidic 1460 — microfluidic ChipShop GmbH

D

Diffusion

The random thermal motion of molecules that spreads a dissolved substance from higher to lower concentration. In laminar co-flow, diffusion is the main way molecules cross the interface between neighbouring streams, so the streams do not mix instantly.

Sources: Theoretical microfluidics (lecture notes, 3rd edition, fall 2006) — Bruus H; Technical University of Denmark (copy hosted on an Aalborg University course page); Microfluidics: Fluid physics at the nanoliter scale — Squires and Quake; Reviews of Modern Physics 77, 977 (2005), Caltech author copy

Double emulsion

Droplets that contain an inner droplet, such as water-in-oil-in-water, used to make capsules with a core and a shell. Secoya's RayDrop double-emulsion configuration uses separate core and shell nozzles.

Sources: Monodisperse double emulsions generated from a microcapillary device — Utada et al.; Science (2005); Microfluidic Double Emulsion Device (RayDrop Double Emulsion) — Fluigent (device developed and manufactured by Secoya)

F

Flow focusing

A droplet-generation geometry in which the continuous phase flows in from both sides and squeezes the dispersed phase through a narrow orifice, where it breaks into droplets. Droplet size and generation behaviour depend on the flow rates, geometry and fluid properties.

Sources: Formation of dispersions using 'flow focusing' in microchannels — Anna et al.; Applied Physics Letters (2003); Machine learning enables design automation of microfluidic flow-focusing droplet generation — Lashkaripour et al.; Nature Communications (2021)

H

Hot embossing and injection moulding

Ways of forming microchannels in thermoplastics. Hot embossing presses a patterned master into a polymer sheet heated to around its glass-transition temperature; injection moulding forces molten polymer into a mould under high pressure, then cools and ejects the part. Both are used for higher-volume chip production, and injection moulding suits making large numbers of identical parts.

Sources: Fabrication Methods for Microfluidic Devices: An Overview — Scott SM, Ali Z; Micromachines (2021); Lithography - Australian National Fabrication Facility – Queensland Node — Australian National Fabrication Facility, Queensland Node

Hydraulic resistance

The ratio between the pressure drop along a channel and the volumetric flow rate through it (ΔP = R × Q), analogous to Ohm’s law for electrical circuits. For a wide, shallow rectangular channel it increases in proportion to channel length and liquid viscosity, and rises steeply as the channel gets shallower—roughly in inverse proportion to the cube of its height.

Sources: Theoretical microfluidics (lecture notes, 3rd edition, fall 2006) — Bruus H; Technical University of Denmark (copy hosted on an Aalborg University course page); Reexamination of Hagen–Poiseuille flow: shape-dependence of the hydraulic resistance in microchannels — Mortensen et al.; Physical Review E (2005), arXiv:physics/0412015

Hydrogel

A water-swollen, cross-linked polymer network. In microfluidic cell culture, gels can be loaded into a chip to give cells a three-dimensional scaffold; AIM Biotech describes its idenTx 3 chip and idenTx 40 plate as compatible with all polymerisable gels.

Sources: Hydrogel: Preparation, characterization, and applications: A review — Ahmed EM; Journal of Advanced Research (2015); idenTx 3 Chip — AIM Biotech; idenTx 40 Plate — AIM Biotech

L

Lab-on-a-chip

A device that integrates one or more laboratory functions—such as sample preparation, mixing, separation, cell lysis or detection—on a single small chip. Such devices typically combine microfluidic channels with components such as electrodes, sensors, pumps or valves to analyse very small fluid volumes.

Sources: BioMEMS: state-of-the-art in detection, opportunities and prospects — Bashir R; Advanced Drug Delivery Reviews (2004); Lab-On-A-Chip Devices (MeSH descriptor) — US National Library of Medicine

Laminar flow

Smooth flow in which liquid moves in orderly layers without turbulent eddies. Because microfluidic channels are narrow and flows are slow, flow is usually laminar, so neighbouring streams travel side by side and mix mainly by diffusion.

Sources: Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies — Sia and Whitesides; Electrophoresis 24, 3563 (2003), course copy hosted by the University of Rhode Island; Microfluidics: Fluid physics at the nanoliter scale — Squires and Quake; Reviews of Modern Physics 77, 977 (2005), Caltech author copy

Luer and Mini Luer connectors

Tapered (conical) fittings, originally standardised for syringes and needles, that are also used as connection ports on many microfluidic chips. ibidi’s µ-Slide VI 0.4 has female Luer ports that accept male Luer tubing connectors, whereas microfluidic ChipShop also offers a smaller Mini Luer chip interface, so check which adapters a setup needs.

Sources: NF EN 20594-1 (ISO 594-1:1986) Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment – Part 1: General requirements — AFNOR (Association française de normalisation); µ-Slide VI 0.4 Instruction Manual — ibidi GmbH; Chips explained — microfluidic ChipShop GmbH

M

O

Open-access fabrication facility

A shared facility that lets external researchers and companies use specialised fabrication equipment after training, or have facility staff carry out the work. In Australia, the Australian National Fabrication Facility (ANFF) provides this model across its nodes.

Sources: About ANFF — Australian National Fabrication Facility Ltd; About us - Australian National Fabrication Facility – Queensland Node — Australian National Fabrication Facility, Queensland Node

Organ-on-a-chip

A microfluidic cell-culture device whose channels are lined with living cells arranged to reproduce key features of a tissue’s or organ’s structure and function. Current chips model only certain aspects of a tissue, so each design focuses on the features that matter for the research question.

Sources: Human Organs-on-Chips — Wyss Institute for Biologically Inspired Engineering at Harvard University; Organs-on-chips: into the next decade — Low et al.; Nature Reviews Drug Discovery (2021; online 2020) – Leiden University repository copy, CC BY 4.0

P

PDMS (polydimethylsiloxane)

A transparent, flexible silicone elastomer widely used to prototype microfluidic chips by casting it on a mould. It is gas permeable and elastic, but it can absorb some small hydrophobic molecules. Emulate’s stretchable Chip-S1 is made from PDMS; its Chip-R1 uses rigid plastics.

Sources: Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies — Sia and Whitesides; Electrophoresis 24, 3563 (2003), course copy hosted by the University of Rhode Island; Chip-R1 Basic Research Kit Data Sheet (EN-023 Rev C) — Emulate, Inc.; Chip-S1 Basic Research Kit Data Sheet (EN-020 Rev E) — Emulate, Inc.

Péclet number (Pe)

A dimensionless number comparing transport by flow with transport by diffusion, Pe = U·w/D, where U is the mean velocity, w a channel width and D the diffusion coefficient. A high Péclet number means a solute travels far along a channel before diffusing across it.

Sources: Microfluidics: Fluid physics at the nanoliter scale — Squires and Quake; Reviews of Modern Physics 77, 977 (2005), Caltech author copy; Chaotic Mixer for Microchannels — Stroock et al.; Science (2002)

Photolithography

Patterning a light-sensitive resist by exposing it to ultraviolet light through a photomask. For PDMS chips, photolithography in a thick resist such as SU-8 is commonly used to make the raised master mould.

Sources: Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies — Sia and Whitesides; Electrophoresis 24, 3563 (2003), course copy hosted by the University of Rhode Island; Lithography - Australian National Fabrication Facility – Queensland Node — Australian National Fabrication Facility, Queensland Node

Porous membrane

A thin sheet with pores that separates two channels in many organ chips. Cells can grow on either side and communicate across it, and in some designs cells can migrate through it. Emulate’s datasheets list a 50 µm-thick membrane with 7 µm pores for Chip-S1 and a 22 µm-thick polycarbonate membrane with 3 µm pores for Chip-R1.

Sources: Chip-S1 Basic Research Kit Data Sheet (EN-020 Rev E) — Emulate, Inc.; Chip-R1 Basic Research Kit Data Sheet (EN-023 Rev C) — Emulate, Inc.; Human cervix modeled in microfluidic organ chip fills key women's health gap — Wyss Institute for Biologically Inspired Engineering at Harvard University (31 May 2024)

R

Residence time

How long liquid spends inside a channel or chamber. The mean (nominal) residence time is the internal volume divided by the volumetric flow rate (τ = V/Q); in practice some of the liquid can stay for longer or shorter times, for example where there are dead zones or recirculation.

Source: Lecture 4: Reactor Tanks – Dispersed Flow, Tanks-in-Series, Residence Time Distribution (1.85 Water and Wastewater Treatment Engineering) — Shanahan P; MIT OpenCourseWare (2006)

Reynolds number (Re)

A dimensionless number comparing inertial and viscous forces, Re = ρ·U·L/η, where ρ is the liquid’s density, U a typical flow speed, L a characteristic channel dimension and η the viscosity. Microfluidic flows usually have low Reynolds numbers, so viscous forces dominate and the flow is laminar.

Sources: Microfluidics: Fluid physics at the nanoliter scale — Squires and Quake; Reviews of Modern Physics 77, 977 (2005), Caltech author copy; Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies — Sia and Whitesides; Electrophoresis 24, 3563 (2003), course copy hosted by the University of Rhode Island

S

SBS/ANSI microplate format

The standardised microplate dimensions—first developed by the Society for Biomolecular Screening (SBS) and now published as ANSI/SLAS standards—that let plates and plate-format devices fit automated laboratory instruments. The footprint standard specifies an outer base of 127.76 × 85.48 mm. AIM Biotech states that its idenTx 40 plate complies with the SBS/ANSI 384-well plate standard.

Sources: ANSI SLAS 1-2004 (R2012): Microplates — Footprint Dimensions — Society for Laboratory Automation and Screening (SLAS) / ANSI; ANSI/SLAS Microplate Standards — Society for Laboratory Automation and Screening (SLAS); idenTx 40 Plate — AIM Biotech

Soft lithography

A group of techniques that replicate micro-scale patterns using an elastomer, usually PDMS. For microfluidic chips, liquid PDMS is cast on a master, cured, peeled off and sealed to glass or another layer to close the channels.

Sources: Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies — Sia and Whitesides; Electrophoresis 24, 3563 (2003), course copy hosted by the University of Rhode Island; Lithography - Australian National Fabrication Facility – Queensland Node — Australian National Fabrication Facility, Queensland Node

Staggered herringbone mixer

A passive mixer with angled grooves in the channel floor that make the liquid rotate and fold as it travels. This stretches the interface between streams so diffusion acts over shorter distances. microfluidic ChipShop's Fluidic 1460 is a catalogue example.

Sources: Chaotic Mixer for Microchannels — Stroock et al.; Science (2002); Herringbone mixer - Mixing and NP production - Fluidic 1460 — microfluidic ChipShop GmbH

Syringe pumps and pressure controllers

Two common ways to drive flow through a chip. A syringe pump advances a plunger to set the volumetric flow rate; a pressure controller sets the driving pressure, and the resulting flow depends on the hydraulic resistance of the system.

Sources: Flow Control Technologies: Comparison between peristaltic, syringe and pressure pumps for microfluidic applications — Fluigent; Theoretical microfluidics (lecture notes, 3rd edition, fall 2006) — Bruus H; Technical University of Denmark (copy hosted on an Aalborg University course page)

T

TEER (trans-epithelial/endothelial electrical resistance)

An electrical measurement across a cell layer used to assess barrier integrity; higher resistance generally indicates tighter junctions between cells. MIMETAS lists TEER measurement for its OrganoPlate 3-lane 64 format, and the Wyss Institute has described organ chips with integrated electrodes for barrier measurements.

Sources: TEER measurement techniques for in vitro barrier model systems — Srinivasan et al.; Journal of Laboratory Automation (2015); Explore the OrganoPlate® Platform for 3D Cell Culture — MIMETAS; Wyss Institute's Organ Chips get smart and go electric — Wyss Institute for Biologically Inspired Engineering at Harvard University (14 June 2017)

W

Wall shear stress

The force per unit area that flowing liquid exerts parallel to a channel wall, and therefore on cells attached to it. Flow-culture protocols often state it in dyn/cm²; the SI unit is the pascal (1 Pa = 10 dyn/cm²). The target shear stress for the cell type is a key setting when planning a cell-culture-under-flow experiment.

Sources: Application Note 11: Shear Stress and Shear Rates for ibidi µ-Slides Based on Numerical Calculations (version 6.1) — ibidi GmbH (2022); NIST Guide to the SI, Appendix B.9: Factors for units listed by kind of quantity or field of science — National Institute of Standards and Technology (NIST)

Definitions are original summaries, checked against the cited sources on 14 Oct 2026 with AI assistance. Specialist review: not recorded. They are general explanations; product-specific statements are attributed to the manufacturer. Suggest a correction.