Each unit has two inlets and one outlet with Mini Luer interfaces.
Manufacturer labels this chip single use and for R&D use only.
Documented specifications
| Field | Published value | Evidence |
|---|---|---|
| Mixing units | 4 unitsOriginal: four functional mixing units | Source |
| Structure A channel depth | 200 µmOriginal: 200 µm | Source |
| Structure A channel width | 600 µmOriginal: 600 µm | Source |
| Structure B channel depth | 100 µmOriginal: 100 µm | Source |
| Structure B channel width | 400 µmOriginal: 400 µm | Source |
Stated applications
Sources & evidence
- Herringbone Mixer — Fluidic 1460 microfluidic ChipShop · Checked 14 Sep 2026
Product identity; Mixing and nanoparticle applications; Materials; Channel geometry; Ports; Research-use statement